| F-120-1
The F-120-1 is used for low frequency susceptibility testing. The useable frequency range is 10 KHz to 175 MHz with an insertion loss of less than 13 dB from I MHz to 125 MHz. The VSWR from 200 KHz to 50 MHz is typically less than 4:1. This very low input VSWR minimizes the power being reflected. The F-120-1 has an input power rating of 100 watts CW for 30 minutes. |
|||||
| ©
2004 Copyright FISCHER CUSTOM COMMUNICATIONS, INC. All rights reserved 20603 Earl Street Torrance, CA 90503 Tel: (310) 303-3300 Fax: (310) 371-6268 E-mail: sales@fischercc.com |
|||||