The F-120-7
is used primarily in low frequency susceptibility testing of signal or
power circuits up to 63 mm in diameter. The useable frequency range is
10 KHz to 150 MHz with a typical insertion loss of 15 dB from 400 KHz
to 110 MHz. The VSWR is less than 4:1 from 200 KHz to 50 MHz. The input
power rating is 125 watts CW for a duration of 30 minutes. |
||||||
![]() |
||||||
| ©