2-Meter EMP Simulator Specifications (For Mil Std 461/462D RS-105 Testing)
Pulse generator: 8 stage Marx bank
Nominal peak E-field range (H-field range): 20 to 75kV/m (53 to 199A/m) in 1kV/m steps
Pulse risetime (10% to 90%): 1.5ns or 4.5ns (manually selectable)
Pulse decay time (peak to 10%): approximately 110-120ns (meets RS-105 requirements). 1/e decay time is approximately 40ns.
Pulse polarity (from top plate to bottom plate): negative
Field uniformity in test volume: +/- 10% maximum
Simulator termination resistance: 120 ohms (nominal)
Time to assemble or disassemble: approximately 8 hours
Pulser controls available: manual, computer controlled (Windows 95/98), or both
OPTIONS (available separately or in conjunction with the EMP simulator)
Complete, computer controlled (Windows 95/98), data acquisition system including:
PC
Digital Storage Oscilloscope (2Gs/s sampling, 500MHz bandwidth)
1 to 4 channels of broadband (1.5GHz) analog fiber optic data link(s)
Field sensors
Software

Click to Enlarge
EMP Simulator Dimensions
EMP Simulator Layout
EMP Simulator Digital Camera
EMP Simulator Control Console
EMP Simulator with fiber optic data links
EMP Simulator showing pulser end
Camera monitoring system including:
PC
1 or 2 digital cameras hardened to 100kV/m
Cameras fiber optic isolated, operate off rechargeable batteries
Camera resolution (NTSC format): 450 (Horizontal) X 480 (Vertical)
Pan, tilt, zoom (10:1) control
Video recorder for frame by frame review, time lapse
Digital capture of video
14 inch color monitor
© 2004 Copyright FISCHER CUSTOM COMMUNICATIONS, INC. All rights reserved
20603 Earl Street • Torrance, CA 90503 • Tel: (310) 303-3300 • Fax: (310) 371-6268
E-mail: sales@fischercc.com