CISPR
22 F-CVP-1
Introduction
The
Fischer Custom Communications, Inc. non-contact capacitive voltage probe
(F-CVP-1) is used to measure the common mode voltage appearing between
a multi-pair balanced cable bundle and the local ground reference for
the cable bundle in accordance with CISPR 22 Section C.1.3 (shown on
the reverse side of this page). The F-CVP-1 makes this voltage measurement
without requiring direct contact with the metallic conductors in the
cable bundle, or requiring physically breaking the cable bundle to install
the F-CVP-1.
The
F-CVP-1 consists of 2 concentric metal electrodes. A capacitive voltage
divider is formed by the capacitance between the cable bundle under
test and the inner metal electrode of the F-CVP-1, and the capacitance
between the inner and outer metal electrodes of the F-CVP-1. A Fischer
Custom Communications, Inc. proprietary circuit buffers and amplifies
the voltage from this capacitive divider, and provides a voltage out
of the F-CVP-1 for direct input into a 50 W signal or spectrum analyzer.
|