FCC-STRPL-8

FCC-STRPL-8G extends the operating frequency range beyond that of existing devices to now permit conducting emissions and immunity testing of integrated Circuits to 8GHz. The IC is mounted on a standardized test fixture (defined in IEC 61967-2) that clamps in place. The 8GHz Stripline accepts ICs that have been mounted on fixtures designed for JM series TEM Cells. Once installed, measurements as per IEC 6196702, SAE 1752-3, and IEC 62132-8 can be performed to 8GHz. For immunity testing, peak electric field levels in excess of 375V/m can be realized with supplied termination.

Product Specifications

Product
Frequency
Input Power Rating
Outer Case Dimensions
Stripline Impedence
Volume
VSWR at input
FCC-STRPL-8 150 kHz - 8 GHz (usable to DC) 2 W with supplied termination (L x W x H) 62 cm x 50 cm x 23 cm - (L x W x H) 7.5 cm x 7.5cm x 2.2 cm <1.6
Product specifications are subject to change without notice