The F-220114-1005-1 is used to measure common mode currents from 10 kHz – 1 GHz. It is for laboratory use by properly trained RF technical personnel using best engineering practices.
Product  | 
												Frequency  | 
												dBΩ (nominal)  | 
												ZtΩ (nominal)  | 
												Connector  | 
												Inner Diameter (mm.)  | 
												Outer Diameter (mm.)  | 
												Height (mm.)  | 
												Max Primary Current DC-400Hz  | 
												
												CW current (amperes)  | 
												Peak Pulse Current  | 
												Calibration Fixture  | 
											
|---|---|---|---|---|---|---|---|---|---|---|---|
| F-220114-1005-1 | 10 kHZ - 1 GHz | - | - | - | 32 | 71 | 19 | 400 | 3 | 100 | FCC-MPCF-3-32-40/71/19 |